Skip to content

Engineering

Software & Visualisation

We write the software that controls your machine, visualises it and passes its data on. The focus is SIMATIC TIA with WinCC visualisation, plus safety-related programming and integration with higher-level systems.

Employee checking a test rig's software on a laptop, with a pneumatic and sensor setup in the background

Scope of services

What is included

PLC programming

Control software in SIMATIC TIA, structured into reusable blocks. New development as well as extending and taking over existing programs.

HMI visualisation

Operator interfaces with WinCC Runtime: operating modes, manual mode, alarm archive, recipe management, user management with permission levels.

Safety-related programming

Safety functions on fail-safe controllers, aligned with the risk assessment and the required performance level.

Dashboards and operating data

Condensed displays for cycle time, availability, scrap and energy. On the panel or in the browser.

Data interfaces

From the classic data block through OPC UA and Modbus to direct handover into QM systems such as Q-DAS and to MES level.

Instruction and training

Handover to your maintenance team including a walkthrough of the program, so nobody is left facing unknown code later on.

Standards

What we work to

DIN EN ISO 13849-1

Safety-related parts of control systems. Determines the required performance level and therefore the structure of the safety software.

DIN EN 60204-1

Electrical equipment of machines. Including requirements for operating modes, emergency stop and restart.

IEC 61131-3

Programming languages for programmable logic controllers. The basis for traceable, maintainable code.

Process

How it runs

  1. 01

    Functional specification

    Before a single line of code is written it is settled what the machine does in each operating mode, including fault cases and restart.

  2. 02

    Software architecture

    Split into blocks, naming convention, interfaces. Structure decided early is structure you cannot save on later.

  3. 03

    Implementation

    Programming in TIA with visualisation developed in parallel. Interim states are demonstrated on a simulation rig, not first at commissioning.

  4. 04

    Testing

    Functional test against the specification, verification of the safety functions, testing the data interfaces against the real target systems.

  5. 05

    Handover

    Runnable program, functional specification, block and variable documentation, and a program walkthrough with your maintenance team. Our own libraries remain know-how protected.

Why CheckTec

Why us

Software from people who also wire cabinets

Our programmers work in the same building as electrical design and assembly. A signal named differently in the diagram than in the code is noticed here before the machine is even built.

Test technology is our origin

35 years of building test systems bring an understanding of measured values, tolerances and traceability that pure machine programmers rarely have.

The data trail does not end at the PLC

Process data is provided so your IT can collect it without asking twice. Documented interfaces instead of grown workarounds.

Siemens partner

Programming is done on the platform of the market leader in industrial automation, with corresponding training and project experience.

Frequently asked questions

Frequently asked questions

Which controller platforms do you program?

The focus is SIEMENS SIMATIC with the TIA Portal and visualisation in WinCC Runtime. Other platforms are possible depending on the project; what matters is what your maintenance team already has and can handle.

Do I get the source code and the rights to it?

You receive the runnable program with full functional, block and variable documentation, so your maintenance team can fix faults and adjust parameters. In-house blocks and libraries remain know-how protected – using the standard protection features of TIA Portal or CODESYS, as is common in the market – and can be licensed for a fee if needed.

Can existing software be extended or taken over?

Yes. Taking over third-party projects is everyday work. Before extending anything we record the status quo: structure, naming conventions and open issues are documented so it stays clear later who wrote what.

How are safety functions implemented?

Based on your risk assessment we determine the required performance level to DIN EN ISO 13849-1. Implementation uses fail-safe controllers and certified safety blocks, and the validation is recorded.

Which interfaces are possible?

Classic data blocks, OPC UA, Modbus, file export and direct integration with QM software such as Q-DAS. Which option makes sense depends on who processes the data afterwards, and how often.

Enquiry

Tell us what it is about

A short description is enough for the first step. If it gets technical, we call.

Your contact

Wadim Rudi

Head of Engineering · PLC Programming

+49 8381 89009-0systems-sales@checktec.de

Prefer to go direct? To the contact page

Step 2 of 3