Skip to content

Systems & Automation

FixCheck, test fixture for single features

Not every inspection task needs a cell. Where a single feature on a stable part has to be judged, a fixture is enough: fixed locator, defined measuring device, unambiguous display. FixCheck is that level, below the automated test cell and above the hand gauge.

In short

FixCheck denotes test fixtures for one clearly defined feature: the part is located precisely, the feature is captured tactilely, inductively, electrically or optically, and the result is shown as pass or fail. The operator does not judge, they load the part and read the result. On request every result is recorded.

01Scope of services

What is included

Precise part location

The locator decides the repeatability. It is designed around the part rather than picked from a catalogue.

Measuring device per feature

Probe, inductive displacement sensor, force sensor, electrical continuity test or a vision sensor, depending on tolerance and accessibility.

Unambiguous display

Pass, borderline, reject. Without a numeric value somebody has to interpret, where the task permits that.

Optional recording

Feature value with a time stamp, where the results are needed by quality assurance.

Poka-yoke features

Design that prevents incorrect loading, so the fixture does not fail because of the operator.

Isometric design view of a row of control cabinets with a top-mounted enclosure

02Components

What sits inside the system

Bought-in components, selected by the task rather than by framework agreement. Which brands are used also depends on what already stands in your plant.

Tactile probe

The classic route to a dimension: defined probing force, high resolution, independent of surface and stray light.

Inductive displacement sensor

Robust and fast, for travel measurement against a fixed reference surface.

Profile sensor

A laser line instead of a probing point, where a contour rather than a single dimension has to be judged.

Vision sensor

Where the check is optical and the task clearly defined, often cheaper than a camera with an evaluation computer.

Standards

What we work to

Measurement capability

A fixture is a piece of test equipment too. Cg/Cgk study or MSA procedure, aligned with your QM requirements.

Traceability of the measuring devices

The probes and sensors used need traceable calibration, otherwise the evidence does not hold.

Process

How it runs

  1. 01

    Feature and tolerance

    Which dimension, which tolerance, which consequence if exceeded. Without those three no fixture can be designed.

  2. 02

    Locator concept

    Determine the datum points on the part, define the clamping concept, check accessibility for the measuring device.

  3. 03

    Design and build

    Mechanics, measuring device, electrics and display, trialled with real parts before delivery.

  4. 04

    Capability verification

    Repeat measurements on defined parts, evaluation of spread and systematic deviation.

Why CheckTec

Why us

Close-up of an assembly station with pneumatic cylinders, sensors and aluminium profiles

The smallest solution that holds

We do not offer a cell where a fixture is enough. That is the faster route to a reliable result and the cheaper one too.

The locator is the actual work

The spread of a fixture almost always comes from the locator, not from the measuring device. That is where the design effort goes.

Extendable towards a cell

A fixture that is later meant to move into an automated test cell is designed for that from the outset.

Frequently asked questions

Frequently asked questions

When is a fixture enough and when do you need a test cell?

A fixture fits one or a few fixed features, a manageable number of variants and a cycle time that allows manual loading. As soon as several views, many variants or unattended inspection are required, the test cell is the right level.

Are fixtures also built without electrics?

Yes. A purely mechanical gauge with a stop and a dial indicator is the right answer in some cases. It has no recording, though, which can be the deciding argument against it where evidence is required.

Can several variants be checked in one fixture?

Via exchangeable inserts yes, as long as the datum points stay comparable. With strongly differing geometry two fixtures are usually cheaper than one overloaded fixture.

Is the capability proof part of the delivery?

It is part of the quotation where you need it. Without proof a fixture creates false confidence, so we agree the procedure with your quality department in advance.

Enquiry

Tell us what it is about

A short description is enough for the first step. If it gets technical, we call.

Your contact

Alois Gruber

Managing Director · Engineering

+49 8381 89009-0sales@checktec.de