Decentralised motor starter · DEMOS

DEMOS, decentralised motor starter with IO-Link

Classic reversing contactor circuits take up cabinet space, create wiring effort and have a limited service life. DEMOS66 moves that function directly to the machine. As a plug-in field device rated IP66, with motor protection and diagnostics via IO-Link.

In short

DEMOS66 is a decentralised, networkable hybrid motor starter for reversing three-phase asynchronous motors from 50 W to 3 kW. It replaces reversing contactors and motor protection in the cabinet, is rated for 3~ AC up to 500 V AC and 3 A output current, and transmits status and diagnostic data such as overload, overload pre-warning, underload and symmetry to the controller via IO-Link.

01Technical data

What the device does

Motor rating
Three-phase asynchronous motors from 50 W to 3 kW, rated for 3~ AC up to 500 V AC and 3 A output current.
Functions
Clockwise, counter-clockwise, motor protection. Safety function optional.
Protection class
Decentralised compact housing rated IP66 for indoor use.
Communication
IO-Link transmitting status messages to the controller: overload, overload pre-warning, underload, symmetry.
Operator interface
LED indication of device status, IO-Link state, device and process faults and direction of rotation; RESET button on the device.
Connection
Standardised MQ-15 power connectors. A quarter turn is enough to connect the motor.
Mounting
Mounting brackets for fixing to machine, conveyor or frame.

02Use cases

Where it pays off

Conveying and transport

Drives along a line, where any central wiring becomes long and expensive.

Modular machine concepts

Machine modules manufactured, tested and plugged in as a unit, without adapting the cabinet per variant.

Retrofit

Replacing worn contactor circuits while gaining diagnostic data at the same time.

Cabinet reduction

Where the existing cabinet is full and a larger one does not fit.

Frequently asked questions

Frequently asked questions

What is a decentralised motor starter and when is it worthwhile?

It sits directly at the motor instead of in the control cabinet. It is worthwhile when many drives are spread over a larger area, when the cabinet is reaching its limits or when machine modules should be pluggable. With few drives close together the classic solution remains more economical.

Which diagnostic data does DEMOS provide via IO-Link?

Status messages to the controller such as overload, overload pre-warning, underload and symmetry. That data is the real added value over a contactor circuit, which either switches or does not.

Is there a safety function?

Optionally. Whether and in what form it suits your application depends on the performance level required by your risk assessment and is clarified per project.

Where is DEMOS manufactured?

In-house in Lindenberg, in the same assembly production that also builds customer assemblies.