Automated force-displacement measurement with a portal on bipolar plates

01Starting point

The challenge

For quality inspection of a fuel cell bipolar plate, part thickness had to be determined at ten defined measuring points under a pre-load of 10 N each. The key was linking the thickness measurement to controlled force application and creating comparable test conditions at every measuring point. The challenge lay in precisely approaching the measuring positions and building up the test force under control. Simple Z-axis positioning was not enough: the actual force had to be captured during the approach and evaluated to control further movement. Only once the pre-load was reached could the corresponding thickness value be accepted.

02Project parameters

Requirements

Test object
Fuel cell bipolar plate
Test task
Thickness inspection under a defined pre-load
Pre-load
10 N per measuring point
Measuring positions
Ten defined points on the bipolar plate
Positioning
Automated XYZ portal
Displacement and thickness measurement
Tactile Keyence GT probe
Force measurement
Load cell capturing the applied force
Approach
Stepwise Z movement via a pulse-value method
Control
Feedback of the measured force to control the approach

03Implementation

Our solution

  • Automatic positioning at ten measuring points: an XYZ portal guides the measuring unit sequentially to the defined positions on the bipolar plate. The fixed sequence enables repeatable inspection of the same part areas.
  • Controlled build-up of the pre-load: the Z axis advances the measuring unit step by step using a pulse-value method, while the applied force is captured via a load cell and evaluated continuously.
  • Force-controlled measuring sequence: the load cell provides the feedback for the further advance. Based on this, the Z movement is adjusted until the defined pre-load of 10 N is reached.
  • Tactile thickness measurement: a Keyence GT probe captures the reading under the defined load, determining the thickness at every test point under a fixed force condition.
  • Point-specific evaluation: force and thickness values are assigned to their respective measuring point, so the ten positions can be assessed individually and differences across the bipolar plate identified.

04Value

The result

  • Comparable measuring conditions: the defined 10 N pre-load creates a consistent basis for the thickness inspection at all ten positions.
  • Reproducible test sequences: automatic approach and controlled advance reduce the influence of manual positioning and force application.
  • Controlled loading: feedback from the load cell enables a precise approach to the target test force.
  • Meaningful part evaluation: measuring at ten defined points reveals local thickness variation under a defined pre-load.
  • Less manual testing effort: positioning, load application and measurement acquisition run in one automated sequence.