Case study · Electronics
Integration and retrofit of a pick-and-place axis in just two days
01Starting point
The challenge
An existing pick-and-place unit for handling PCB assemblies needed a mechanical and control system upgrade. Besides replacing the axis, the focus was on renewing the PLC control and migrating the entire retrofit-related communication from PROFIBUS to PROFINET. Wiring and the energy chain were also to be completely replaced. The biggest challenge was the narrow time window: only two days were available for the conversion and integration into the existing system. That required the mechanics, electrical installation, software and interfaces to be prepared and coordinated in detail beforehand. In addition, the pick-and-place unit was embedded in a cross-line process: communication with neighbouring systems and with production data acquisition had to be accounted for during the modernization and carried over into the new control structure.
02Project parameters
Requirements
03Implementation
Our solution
- Detailed preparation of the conversion: mechanical connections, electrical execution and communication interfaces were coordinated in advance. A planned conversion sequence with a clear order formed the basis for carrying it out within the narrow time window.
- Integration of the CheckTec standard axis: the standardized axis system was adapted to the installation situation and the required pick-up and placement positions. It takes over the pick-and-place motions of the PCB assemblies within the existing system.
- Integration of the pneumatic gripper: the gripper control was linked to the axis movements and the releases from the stations involved, so pick-up, transport and placement run in a defined sequence.
- Modernization of the PLC control: the control software was matched to the new axis solution and the existing plant function. Motion sequences, interlocks and status messages were integrated into the modernized control.
- Migration to PROFINET: the previous PROFIBUS communication was replaced by PROFINET within the retrofit scope, accounting for the required signals and interfaces to the connected systems and to production data acquisition.
- Renewal of wiring and energy chain: the cable routing was completely rebuilt. A new energy chain guides the moving cables along the axis, creating an orderly installation matched to the motion.
- Conversion and integration in two days: thanks to the extensive preparation, the replacement, electrical integration and commissioning were carried out within the planned two-day window.
04Value
The result
- Short conversion window met: the modernization and integration were completed within two days, limiting the necessary production interruption.
- Existing system modernized in a targeted way: the axis system, PLC control and communication were renewed and integrated into the existing production environment.
- Standardized handling solution: the CheckTec standard axis creates a uniform technical basis for operation, maintenance and later adaptations.
- Consistent information exchange: communication with neighbouring systems and with production data acquisition was carried over into the modernized solution.
- Renewed cable routing: new wiring and energy chain replace the previous installation and improve clarity for maintenance and service.
- Defined pick-up and placement: the interplay of axis, pneumatic gripper and PLC enables repeatable handling sequences for the PCB assemblies.